Continuous preparation of NPK, urea, ammonium nitrate, and micronutrient solutions for fertigation and bulk storage.
Coefficient of Variation (CoV) ≤0.05 at inline concentration analyser. Wide turndown (10:1) for seasonal irrigation demand variation. pH control critical for nutrient stability (phosphate precipitation at wrong pH).
Preferred MOC: FRP or HDPE mandatory for most fertiliser solutions. 316SS acceptable for urea. Carbon steel must not contact ammonium nitrate (oxidiser classification). PVDF or FRP injection quill.
Ammonium nitrate: classified oxidiser — no ferrous metal contact, no dead legs, anti-static earthing. Phosphate solutions: pH monitoring to prevent calcium phosphate precipitation. Wide turndown in irrigation systems must maintain uniform dosing.